Lab.Gruppen (P)LM Series module preset suitable for TW AUDiO VERA S32 speaker

Preset version: 3.12

Application notes:
* VERA S32 in hypercardioid mode; you might use this preset with single speaker stacks

Technical info:
* Amp Gain is 32 dB
* Set MaxPeak Level to 3 dB for usage with PLM(+) Series
* Set MaxPeak Level to 0 dB for usage with LM44 or LM26

Support information:
* E-Mail:   support@twaudio.com
* Internet: https://twaudio.de/en/
* Phone:    +49 (0) 71 41 - 48 89 89 55

Compilation date: 04/12/2024